Baxi Bermuda 51 5 Installation Manual

Baxi Bermuda 51 5 Installation Manual

Baxi Bermuda 51 5 Manual Baxi Bermuda 51/5 Outset Back Boiler Unit Spares. And instruction book and installation manual. Will also fit on a Baxi Bermuda Back Boiler. Install Afm Fonts Windows 10 on this page. Baxi Bermuda 51/5; Baxi Bermuda 57/3E; Baxi Bermuda 45/3M; Baxi Bermuda 57/3M; Baxi Bermuda 401; Baxi Bermuda 552; Baxi Bermuda 553 Propane; Baxi Bermuda 675 PW.

• Please keep these Instructions safe. Should you move house, please hand them over to the next occupier.

Baxi Bermuda PW5 Deluxe/C5/C5W Fireside Gas Central Heating Unit Installation and Servicing Instructions PW5 Deluxe. • Everyone who works at Baxi has a commitment to quality because we know that satisfied customers mean continued success. We hope you get a satisfactory service from Baxi. If not, please let us know.

Baxi is a BS-EN ISO 9001. Intel Parallel Studio Download Crack Fifa. • Codes of Practice, most recent version Information should be used In GB the following Codes of Practice apply: Safe Installation Standard Scope BS 6891 Gas Installation.

BS 5546 Installation of hot water supplies for The appliance is suitable only for installation in domestic purposes. • Installation Instructions Ventilation Ventilation air supply should be in accordance with the relevant standards. In GB this is BS 5440 Pt. In IE this These instructions must be read in conjunction with the is I.S. 813 “Domestic Gas Installations”.

Baxi Bermuda 51/5 Manual

The permanent separate instructions for the boiler section ventilation area size requirements are INTRODUCTION. • Fitting the Fire Bend the central flap of the backing plate and the two securing brackets as shown in the diagram. In) C5W Fireplace 560mm 660mm Min.

Backing Plate Opening (26in) PW5 &C5 (22in) Hearth Level 406-584mm (16-23in) PW5 991mm Min. • Commissioning the Fire 12.Hand the user the User’s Instructions, explain the operation of the boiler and fire and leave the unit set to suit their requirements. Remove the four radiants from their packing.

Fit them by inserting their upper edge into the heat exchanger 13.Leave these instructions with the user or adjacent to and then lowering them on to the burner rail. • Fire Flue Spigot Casting Boiler Draught Diverter End Baffle - Fire Flue Spigot Smoke Tube Spillage Clearance Inserted Checked Here Smoke Match Approx. Smoke Match Door - Boiler Fire Boiler Smoke Match Position Combustion Box Fig.7 Spillage Test Fig.6 Pilot Viewing Window Fire Control Knob 76mm Indicator Light. • Servicing the Fire Changing Components CAUTION: ISOLATE THE ELECTRICAL SUPPLY. TURN CAUTION: ISOLATE THE ELECTRICAL SUPPLY, TURN OFF THE GAS SUPPLY, ENSURE THAT THE FIRE IS OFF THE GAS SUPPLY, ENSURE THAT THE FIRE IS COLD, TEST FOR GAS SOUNDNESS UPON RE- COLD, AFTER REPLACING ANY COMPONENTS ASSEMBLY. • F.F.D./Electro-Magnet Unit individual component.The complete assembly must be replaced in the event of one or other component Piezo Igniter failure(s). Only use a Genuine Baxi Spare Part.

Release the thermocouple and pilot feed pipe from the gas tap connection points. • Fault Finding Chart BAXI BERMUDA C5 / C5W / PW5 DELUXE Gas Type G20 (Natural Gas) Does the START pilot ignite? Turn on gas supply there a strong gas supply spark at the turned on? Adjust spark gap. • Does Fire satisfactory the fire remain alight?

Comments are closed.